Product Details
Free Worldwide Express Shipping for this unit - Fully Insured
This unit has been calibrated and fully tested twice to Tektronix manufacturers specification by Trescal (formerly Qinetiq/ASAP Calibration). Here is a copy of the latest certificate:
Tektronix SCD5000 Certificate of Calibration
Previous certificate will also be included.
Tektronix SCD5000 Option 01, 1P. Transient Digitizers Waveform Recorders
Option 01: Delay Line and Internal Trigger Pickoff
Option 1P: Fast Waveform Capture increases waveform captures from one to ten 512 point waveforms per second
Condition: Excellent Condition. Full Working Order.
-
Previously used and maintained by MOD (Ministry of Defence) and BAE (British Aerospace)
-
SCD5000 Tested and complied with manufacturer's specification
-
Operational checks and calibration by Trescal (formerly Qinetiq/ASAP Calibration) who have done calibration for Defence and other high-tech industries.
-
User Manual (070-6960-02) PDF file
-
Programmers Manual (070-7315-02) PDF file
More information:
ULTRA HIGH-SPEED TRANSIENT DIGITIZERS
SCD SERIES TRANSIENT WAVEFORM RECORDERS
-
High single-shot sample rate to 200 GS/s
-
High analog bandwidth
-
Time resolution to 5 ps per point
-
Variable record length from 256 to 1024 points
-
Display unit for easy control, viewing, and measurements
APPLICATIONS
-
Laser measurements
-
Accelerator diagnostics
-
EMP and radiation testing
-
Nuclear effects
-
Telecommunications
-
EMC/EMI measurements
-
Radar and lidar
-
nuclear events
-
pulsed power sources
-
analysis of fast pulsed events
-
high energy physics
-
fluorescence decay
-
high frequency ultrasonics
HIGH PERFORMANCE CAPTURE
The SCD5000 and SCD1000 are designed to capture low nanosecond and picosecond single-shot events. Whether the application involves Laser, ESD, EMP, Accelerators or other high-speed single-shot phenomena, the SCD series waveform recorders can capture the event with excellent fidelity.
The maximum acquisition rate of 200 GS/s provides time resolution to 5 ps. With time windows from 5 ns to 100 µs, the SCD series recorders provide flexible acquisition windows. When the delay line is used, approximately 2.5 ns of pretrigger information can be captured.
The SCD5000 uses direct access with input sensitivity of 5 V and offset of ±4.0 V. The SCD1000 provides quality conditioning of the input signal with 100 mV to 10 V full scale ranges, dc offset and ac or dc coupling. There are two input channels which can be configured to multiplex two signals or algebraically add or subtract two input signals to the single channel waveform recorder.
The waveform record length is selectable between 256, 512 or 1024 data points. With 16 built-in waveform locations, multiple trigger events can be stored into separate storage locations. Each record is time and date stamped for later comparison. There are 10 nonvolatile settings storage locations for quick instrument setup.
STAND-ALONE OR SYSTEM SUPPORT
The SCD Series recorders are designed for use in either a stand-alone or a system environment. With the standard display unit, SCD waveform recorders allow full control of operation, viewing of up to 4 waveforms and cursor measurements.
In a system environment, there is a high-speed GPIB interface and commands to make data acquisition flexible and fast.
OPTIONS EXPAND CAPABILITY
A fast waveform capture option (Opt, 1 P) increases the capture rate by ten times, from one waveform per second to ten waveforms per second.
There is a choice of input connectors in addition to the the standard Type-N connector. On the SCD1000, a choice of SMA or Tek Type II intelligent probe interface are available. On the SCD5000, SMA connectors can be chosen.
CHARACTERISTICS
The characteristics are divided into 3 parts:
• Vertical characteristics for all SCD series recorders
• Trigger characteristics for all SCD series recorders
• SCD series common characteristics
|
VERTICAL |
|
|
Parameter |
SCD5000 Opt 01 |
|
Bandwidth |
3.0 GHz |
|
Rise time |
120 ps |
|
Input Range |
±5Vdirect access |
|
Offset |
±4 volts |
|
Invert |
No |
|
Input Impedance |
50?, DC coupled |
|
Coupling |
DC |
|
Maximum Input Voltage |
5 Vrms (0.5 W) or 0.25 W-sec. Pulses not exceeding 25 V peak |
|
VSWR |
|
|
Vertical resolution |
11 bits |
|
TRIGGERING |
|
|
Parameter |
SCD5000 Opt 01 |
|
Source |
External and internal analog |
|
Coupling |
AC only |
|
Slope |
Positive or Negative |
|
Level range |
External analog; ±1.25 V in 10 mV steps. |
|
Sensitivity (sinewave) External input |
50 mV, 20 kHz to 50 MHz |
|
Sensitivity (sinewave) Internal input |
500 mV, 20 kHz to 50 MHz |
|
Sensitivity (pulse) |
150 mV with minimum of 500 ps HAD (halt amplitude duration) pulse. |
|
Pretrigger view time |
2.5 ns |
SCD SERIES COMMON CHARACTERISTICS
Time per Point - 5 ps/point (5 ns time window with 1024 point record length) to 400 ns/point (100µs time window with 256 point record length).
Time Windows - 5 ns to 100 Ns in a 1, 2, 5 sequence of 14 steps.
Trigger delay - 0% to 500% of time window with 0.06% resolution.
DIGITIZING
Record Length -256, 512 or 1024 waveform data points.
Internal Calibration - Internal signal standards for increased accuracy of vertical range, dc offset, trigger level, and window size.
Multiple Records - 16 waveform locations (first 4 locations are battery backed up).
Auto Advance Mode -Automatic capture of sequential events into separate waveform locations.
Time Stamping - Time and date stored with every acquisition.
SYSTEM CAPABILITIES
GPIB - IEEE-488.1 interface is standard for instrument control and waveform data transfer. Maximum transfer rate ? 500 kilobytes/s. Instrument functions, settings, and operating modes are programmable, with the exception of the power switch.
Waveform Data Formats - Either processed (using centroid algorithm) or raw waveform data available.
Settings Storage - 10 nonvolatile instrument settings.
System commands - Examples of commands include:
• Advance data into multiple waveform locations (16)
• NRepeat makes user specified single-shot acquisitions and automatically transfer to controller
• Calibrate command for increased time and amplitude accuracy
• Data Count allows partial waveform transfers
DISPLAY UNIT
Compatibility - Attaches to any SCD Series waveform recorder.
Menu Functions - Instrument settings and operating modes are programmable from the display unit.
Waveform Display - Up to 4 waveforms displayed.
Local Cursor Measurements - Volts, ?Volts, Time, ?Time, and 1/?Time on one waveform or between any two waveforms.
SIGNAL CONNECTIONS
Gate out - Single BNC connector on back panel, output TTL level pulse is coincident with start of sweep.
Video out -TTL, VGA (600 x 400 resolution) compatible video signal output on back panel. Compatible with standard PC multiple-frequency monitors and video hardcopy units.
POWER
Line Frequency - Operational from 48 to 440 Hz.
Power Consumption - SCD5000: ?250 Watts maximum fully optioned. SCD1000: ?300 Watts maximum fully optioned.
Line Voltage Range -90 to 132 Vrms (115 V); 180 to 250 Vrms (230 V).
ORDERING INFORMATION
SCD5000 4.5 GHz Waveform Recorder MSRP: $46,900
Includes: Standard configuration with detachable display unit and Type N connectors, power cord, Instruction Manual (070-6960-00), Instrument Interfacing Guide (070-7315-00) Quick Reference Card (070-7316-00), rackmount hardware.
OPTIONS
Opt 1P - Increase waveform capture rate from one to ten 512-point waveforms per second. MSRP: +$3,000
Opt 01 - Add delay line with Internal trigger pickoff (SCD5000 only). MSRP: +$3,000
PHYSICAL CHARACTERISTICS
Width: 19 in. - 482.6 mm
Height: 7 in. - 177.8 mm
Depth: 30 in. - 762 mm
Net Weight: 54 lbs. - 24.5 kg
![]() |
|